Maintenance
54
Pos: 24.33.10 / BA/Wartung/Mä hwerke/Messerschr aub / Mess erschnellverschlus s/Messerschr aubverschluss Halt ebolzen 14 m m @ 0\mod_ 119726790737 5_78.docx @ 1 6425 @ @ 1
10.10.2 Blade screw connection
Danger! - Insufficient thickness of material on the retaining bolts.
Effect: Danger to life or serious injuries.
• At every blade changing check the thickness of the holding bolts material.
• Damage or worn retaining bolts must always be replaced by sets on each cutting
disc/blade drum!
• The material thickness of the retaining bolts must not be less than 14 mm at the weakest
point.
EC-240-0
min. 14 mm
Fig. 30
Pos: 24.33.11 / BA/---------- -----Seitenumbruch---- ---------- -- @ 0\mod_1196175 311226_0.doc x @ 4165 @ 2 @ 1