16. BATTERY/CHARGING SYSTEM
16-6
GRAND DINK 125/150
A.C. GENERATOR REMOVAL
A.C. generator removal (
!
10-3)
A.C. generator installation (
!
10-6)
REGULATOR/RECTIFIER
INSPECTION
Remove the frame front cover. (
!
2-5)
Remove the regulator/rectifier wire coupler.
Check the continuity between the wire
terminals.
Normal Direction: Continuity
(+) Probe
(-) Probe
I
Yellow
Green
II
Red/Black
Yellow
Reverse Direction: No Continuity
(+) Probe
(-) Probe
I
Green
Yellow
II
Yellow
Red/Black
VOLTAGE REGULATION TEST
Connect a voltmeter across the battery
terminals.
Start the engine and gradually increase the
engine speed.
The battery terminal voltage should be within
14.0_ 15.0V.
A.C. Generator Stator
Voltage Sensor
Black
Regulator/Rectifier
Bolts
Pulser Coil
Right Crankcase Cover
Green
Red/Black
Normal
Direction
Reverse
Direction
Yellow