17. IGNITION SYSTEM
17-3
GRAND DINK 125/150
SPARK PLUG
For spark plug inspection and adjustment,
refer to page
3-5.
IGNITION COIL INSPECTION
Remove the seat and met-in box. (
!
2-3)
Remove the ignition coil
IGNITION COIL CONTINUITY TEST
Inspect the continuity of the ignition coil,
primary coil and secondary coil.
Measure the ignition coil resistances at
20 .
SECONDARY COIL WITH PLUG CAP
Primary coil
0.16_ 1W
Secondary coil
without plug cap
3.4_ 4.6KW
Secondary coil with
plug cap
7.6_ 9.6KW
SECONDARY COIL WITHOUT PLUG
CAP
Ignition Coil
AC 110V
This is a general test. Accurate ignition
coil test must be performed with a CDI
tester.
Ignition Coil
Secondary Coil
Primary Coil
Ignition Coil