EasyManuals Logo
Home>Lenze>Conference System>E84DGFCp Series

Lenze E84DGFCp Series User Manual

Lenze E84DGFCp Series
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Communication manual 8400 motec PROFIBUS
Error messages
Possible causes and remedies
78 L EDS84DMOTPBUS EN 3.0 - 11/2011
12.2 Possible causes and remedies
This chapter contains all PROFIBUS error messages in numerical order of the error number.
Possible causes and remedies as well as responses to the error messages are described in
detail.
Tip!
An alphabetical listing of all PROFIBUS error messages can be found in the previous
chapter "Short overview (A-Z) of the PROFIBUS error messages
" ( 77).
Lost connection to 8400 base device [0x01bc3100]
Memory. No access [0x01bc5531]
Memory. Read error [0x01bc5532]
Memory. Write error [0x01bc5533]
Internal error [0x01bc6010]
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Network cable (plug) is defective.
Network cable is not connected to PROFIBUS
connection.
Voltage supply is interrupted.
Check cables and terminals.
Connect network cable to PROFIBUS connection.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access to memory was not possible. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be read. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be written. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No response System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication unit is defective. Send the device and a description of the fault to Lenze.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84DGFCp Series and is the answer not in the manual?

Lenze E84DGFCp Series Specifications

General IconGeneral
BrandLenze
ModelE84DGFCp Series
CategoryConference System
LanguageEnglish

Related product manuals