EDS84DMOTPBUS EN 3.0 - 11/2011 L 79
Communication manual 8400 motec PROFIBUS
Error messages
Possible causes and remedies
Restart after watchdog reset [0x01bc6011]
Internal error [0x01bc6100]
Internal error [0x01bc6101]
Internal error [0x01bc6110]
Invalid parameter record [0x01bc641f]
Error: Lenze settings loaded [0x01bc6420]
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication unit is defective. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication unit is defective. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication unit is defective. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Communication unit is defective. Send the device and a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No response System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
No active parameter set could be loaded. Repeat the download of the application (including
module).
Response (Lenze setting printed in bold) Setting: not possible
No response System fault : Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access to the parameter set in the memory module via
the standard device failed.
Repeat the download of the application (including
module).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze E84DGFCp Series and is the answer not in the manual?

Lenze E84DGFCp Series Specifications

General IconGeneral
BrandLenze
ModelE84DGFCp Series
CategoryConference System
LanguageEnglish

Related product manuals