21 Maintenance
WARNING!
Risk of injury when working on the bed!
Ensure that the bed is disconnected from the mains power prior to installation, putting into service, maintenance
and deinstallation.
Ensure that the castors are locked prior to installation, putting into service, maintenance and deinstallation.
WARNING!
Risk of injury due to defective bed!
Have a defective bed repaired immediately.
If the defect cannot be repaired, do not use the bed.
CAUTION!
Material damage due to incorrect maintenance!
Ensure that maintenance is performed exclusively by manufacturer´s customer service or by authorised service
personnel certied by the manufacturer.
If the defect cannot be repaired, do not use the bed.
LINET ® recommends attaching the maintenance plaque to the bed.
21.1 Regular maintenance
Check regularly movable parts for wear.
Perform regularly visual check of the product (with delivery note if necessary).
Ask service department of the manufacturer for addition of the original spare parts if some product parts are missing.
Ask service department of the manufacturer for replacement of any damaged product parts by the original spare parts.
Check that the accumulator is working properly. Disconnect the bed from the mains power to check signalisation of
accumulator indicator according to the instructions for use.
Have the accumulator replaced if it is not working properly.
Check regularly that all accessories are working properly.
Replace damaged accessories immediately.
21.2 Spare Parts
The serial label is located on the frame of the mattress support platform. The serial label contains information for claims and orde-
ring replacement parts.
Information about spare parts is available from:
Manufacturer´s customer service
Sales department
21.3 Safety Technical Checks
WARNING!
Risk of injury due to incorrect safety technical checks!
Ensure that safety technical checks are performed exclusively by manufacturer´s customer service or by authori-
sed service personnel certied by the manufacturer.
Ensure that the safety technical checks are recorded in the service and maintenance log.
Safety technical check of the medical bed must be performed at least once every 12 months.
The procedure for performing the safety technical check is stipulated in EN 62353:2014.
NOTE On request, the manufacturer will provide service documentation (e.g. circuit diagrams, component part lists, descriptions,
calibration instructions etc.) for service personnel for the repair of ME equipment designated by the manufacturer as repairable by
service personnel.