Manitowoc Published 12-05-17, Control # 032-23 3-25
18000 OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
Table 3-3 Bypassable Limit Identification — Crane Serial Number 18001082 and Newer
Limit
Limit Bypass Switch (D8)
(momentary key switch)
Limit Bypass Switch (D8)
(momentary key switch)
Luffing Jib Setup Mode On
1
External Override
Switch
2
Non-CE
3
CE
3
Non-CE
3
CE
3
CE
3
MAX UP 1 (Boom)
No
No No No No
BLOCK UP (each drum) Yes Yes Yes Yes No
MIN BAIL (each drum) Yes Yes No No No
LOAD MOMENT (RCL/RCI) Yes
Yes
4
No No
Yes
5
MAX UP 1 (Luffing Jib) Yes No Yes Yes No
MAX UP 2 (Luffing Jib)
Yes
6
No
Yes
6
Yes
6
No
MAX DOWN 1 (Luffing Jib) Yes No Yes Yes No
MAX DOWN 2 (Luffing Jib) Yes No Yes No No
MAST TOO FAR FORWARD Yes Yes No No No
1
Use only for rigging.
2
See Rated Capacity Indicator/Limiter Operation Manual.
3
CE = Cranes that comply with 2010 European requirements.
4
Only while operating between 100% and 110% rated capacity. The speed of the crane functions is limited to 15% of their
maximum speed for movements that increase load.
5
The speed of the crane functions is limited to 15% of their maximum speed for movements that increase load.
6
Only when boom is below 50°