Malfunctions during crane operation
14.3 Warning and error messages
14 - 8 3 302 709 en Operating manual
GMK5150L
12.01.2018
14.3.2 Error messages on the CCS display
•
Stop all crane movements and bring both control levers into the initial
position.
The symbol (1) or (2) flashes when the CCS
has detected an error. The symbols flash
alternately when both error types are present.
(1) – Engine/transmission error
• Switch off the engine immediately.
• Open the Engine/transmission error menu (3).
For the subsequent procedure;
à p. 8 - 17.
(2) – Crane operation error
The buzzer tone sounds once.
• Open the Crane operation error menu (4).
Display of error / total errors
Display (3) shows the error total, and
display (2) shows which error is displayed.
3/5, for example, means:
– Error 3 is shown
– A total of 5 errors are pending.
Displaying errors
The rotating symbol (1) indicates that further
unacknowledged errors are present.
• Select and acknowledge the symbol (4)
or (5) to show any additional errors.
G
Risk of accidents
Immediately stop operating the crane if an error message is displayed.
The crane control may only be repaired by qualified personnel.
4 Previous error
5 Next error

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK5150L and is the answer not in the manual?

Manitowoc GROVE GMK5150L Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK5150L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals