Crane operation
11.7 Working range limiter
11 - 142 3 302 709 en Operating manual
GMK5150L
12.01.2018
11.7.5 Enter limit values – for the slewing range
– For unknown limit values, you can approach a shut-off point and accept
the current slewing angle as Accept limit value.
– If the limit values are known, you can Manually enter limit value.
Switch off monitoring
Before you enter a limit value, you must
switch off the monitoring.
• Select and confirm the symbol (1).
The
Slewing range monitoring is switched off.
Displays
Permissible slewing range
– The slewing angle A limits slewing to
the left.
– The slewing angle B limits slewing to
the right.
The permissible slewing range (6) – green –
is the angle from A clockwise to B.
G
Danger of accident due to incorrectly set limit values!
When entering the limit values, please note that movements can still take
place even after switching off, which lead further into the shutdown range.
Before crane operation, slowly approach all limit values, check that they are
shutdown in good time and, if necessary, enter new limit values with larger
safe distances.
1, 3, 5 Current slewing angle
2 Limit value for the slewing angle A
4 Limit value for the slewing angle B

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK5150L and is the answer not in the manual?

Manitowoc GROVE GMK5150L Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK5150L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals