Chapter 6 Digital I/O
X Series User Manual 6-22 ni.com
Using a Digital Source
To use DO Pause Trigger, specify a source and a polarity. The source can
be one of the following signals:
• PFI <0..15>
•RTSI<0..7>
•PXI_STAR
• PXIe-DSTAR<A,B>
•Counter n Internal Output
•Counter n Gate
•AI Pause Trigger (ai/PauseTrigger)
•AO Pause Trigger (ao/PauseTrigger)
•DI Pause Trigger (di/PauseTrigger)
The source also can be one of several other internal signals on your DAQ
device. Refer to Device Routing in MAX in the NI-DAQmx Help or the
LabVIEW Help for more information.
You also can specify whether the samples are paused when DO Pause
Trigger is at a logic high or low level.
Using an Analog Source
When you use an analog trigger source, the samples are paused when the
Analog Comparison Event signal is at a high level. Refer to the Triggering
with an Analog Source section of Chapter 11, Triggering, for more
information.
Routing DO Pause Trigger Signal to an Output
Terminal
You can route DO Pause Trigger out to any RTSI <0..7>, PFI <0..15>, or
PXIe-DSTARC terminal.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments DAQ X Series and is the answer not in the manual?

National Instruments DAQ X Series Specifications

General IconGeneral
BrandNational Instruments
ModelDAQ X Series
CategoryI/O Systems
LanguageEnglish

Related product manuals