Calculating Melter Power Requirements
A-1
Part 1032059B
E 2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
Appendix A
Calculating Melter Power Requirements
Before locating the melter on the production floor or attaching hoses and
guns to the melter, you must calculate the electrical power required by the
hoses and guns and confirm that the required power does not exceed
maximum allowable wattages. Properly calculating melter power
requirements will prevent damage to the melter and identify the maximum
allowable distance between the melter and the point at which the hot melt is
dispensed.
The following three maximum wattages must be considered when
calculating melter power requirements.
S Single-component maximum—The wattage of any single hose or
gun
S Hose/gun pair maximum—The combined wattage of any hose and
gun (hose/gun pair)
S Two hose/gun pair maximum—The combined wattage of hose/gun
pairs 1 and 2
If your Nordson representative has already calculated the hose/gun power
requirements and confirmed that the maximum allowable wattages will not
be exceeded, then no further calculation is necessary. However, you should
re-evaluate the hose and gun power requirements before you:
S add a new hose or gun to the melter that was not factored into the
original wattage evaluation
S replace an existing hose with a longer hose or an existing gun with a
larger gun