Running by Virtual External Inputs Section 8-4
179
2. Select [Debugger program area (UM2)] in [UM Access Enable] followed
by clicking the [OK] button.
3. After confirming that the CX-Simulator is connected in the [Work CX-
Simulator] window, download the ladder program from the CX-
Programmer.
4. After the download is completed, select [UM Settings] in [System Status] |
[Settings] again and select [Application program area (UM1)] in [UM Ac-
cess Enable]. Also, check both boxes for [Application program area
(UM1)] and [Debugger program area (UM2)] in [UM Execution Enable],
followed by clicking the [OK] button.
5. Select [Save all] in the [CX-Simulator Debug Console] | [File] menu to
save the status before starting virtual external inputs.
6. Clicking the [Continuous Run] button from [CX-Simulator Debug Console]
or turning the mode of the Ladder Engine to Monitor from the CX-
Programmer will start running using virtual external inputs.
Note The CX-Simulator can not debug a ladder program in the program area for
debugging. Before downloading the ladder program to the program area for
debugging, check it in the area for applications in advance.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for Omron CS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CS Series and is the answer not in the manual?

Omron CS Series Specifications

General IconGeneral
BrandOmron
ModelCS Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals