System Status Setting Window Section 3-7
60
3-7-2 Setting Menu of System Status Setting
Selecting the [Settings] button in the [System Status Setting] window will dis-
play the [Settings] menu. The [Settings] menu sets operation environment for
the CX-Simulator. The [Settings] menu provides the following eight items to
set various operation environments.
Name Function
PLC Selection Create a new PLC (the PLC Setting wizard) and
select an existing PLC. Refer to 3-5 Creating a New
PLC for the details.
Register PLC Unit Set the Unit for mounting to the PLC.
Network Communica-
tions Setting
Set for the Network Communications Unit. Refer to
6-2 Network Communications Settings for details.
Serial Communications
Setting
Set for the Serial communications Unit. Refer to 5-2
Serial Communications Settings for details.
UM Setting Change the UM setting.
PLC Clock Setting Set the cycle time mode, the interval for continuous
run, and others.
PLC Operation Setting Set WDT Disable, DIP switches, and others.
PLC Initializing Initialize the IO memory of the PLC.
Note Changing the node address of the communications unit in the [Network
Communications Setting] will restart the Ladder Engine. Restarting the Ladder
Engine will clear the I/O memory areas according to the PLC Setup and read
the Autoexec file automatically.
3-7-3 Register PLC Unit
The unit selection performed in the [PLC Setup] wizard can be done again in
the [Register PLC Unit] window.
1,2,3…
1. Selecting [Register PLC Unit] in the [System Status Setting]|[Settings]
menu will display the [Register PLC Unit] window.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr