System Status Setting Window Section 3-7
64
3-7-6 PLC Operation Settings
The [PLC Operation Settings] window allows to set for PLC operation.
1,2,3…
1. Selecting [PLC Operation Settings] in the [System Status Setting] | [Set-
tings] menu will display [PLC Operation Settings] window.
· Replay from the top of the
same scan after online…
Set whether or not to enable online edit when
Scan Replay/Step Run.
· Disable Cycle time
watching
Disable the watchdog timer (WDT). The Watch
Cycle Time in the PLC Setup and the WDT
instruction setting are disabled. When disabled,
a CPU error will not occur even if the cycle time
exceeds the setting.
· DIP Switch Settings Set the equivalent setting to the DIP switches
of the CPU Unit.
· UM Automatic Boot Set to read Autoexec file automatically when
the power turns ON (When the Ladder Engine
is started.).
· User Switch Set the DIP Switch (A39512) for User-
customization.
· OK Save the current settings and exit the window.
· Cancel Discard the current settings and exit the win-
dow.
2. Click the [OK] button when setting is completed.