Input
63
11 .09 Sewing motor errors
1 Time out
9 Position not reached
34 Brake path too short
35 Communication error
36 Initialisation (Init.) not completed
65 Extint low at Init
66 Short circuit
68 Extint low in operation
69 No increments
70 Motor blocking
71 No incremental connector
73 Motor running interrupted
75 Controller locked
170 Invalid transmission
171 Zero mark invalid
175 Start error
222 Time-out monitoring
11 .10 OTE-errors
1 Read error
2 Write error
3 Full EEPROM
4 No EEPROM
5 Invalid size
6 Invalid address
7 Address overfl ow
8 Checksum falled
9 Serialnr. changed
7 Adressen-Überlauf
8 Checksummen-Fehler
9 Falsche Seriennummer
ERROR: 409 Zero point not found
ERROR: 416 Error in SD-memory card reader
1: No SD-memory card inserted
2: Wrong SD-memory card (does not match the machine)
3: SD-memory card not inserted correctly
4: SD-memory card with write protection
5: Data error on SD-memory card
6: Formatting failed
7: File does not match machine
8: Incorrect fi le size
9: Transfer error
10: Data cannot be deleted
11: Sewing head recognition unit not connected
ERROR: 417 No penetration point found for winding
ERROR: 418 1st penetration point for winding is located outside the sewing area
ERROR: 419 Incorrect number of sewing-on stitches
ERROR: 420 Incorrect number of attaching stitches