1.4 Installation notes
RAD-2400-IFS and RAD-868-IFS only: Phoenix Contact hereby declares that this
wireless system complies with the basic requirements and other relevant regulations
specified in Directive 2014/53/EC.
RAD-2400-IFS and RAD-868-IFS only: The category 3 device is suitable for installa-
tion in Zone 2 potentially explosive areas. It meets the requirements of EN 60079-
0:2012+A11:2013 and EN 60079-15:2010.
Installation, operation, and maintenance may only be carried out by qualified electri-
cians. Follow the installation instructions as described.
When installing and operating the device, the applicable regulations and safety direc-
tives (including national safety directives), as well as general regulations applicable to
the technology, must be observed. The technical data is provided in the packing slip
and on the certificates (conformity assessment, additional approvals where applica-
ble).
Do not open or modify the device. Do not repair the device yourself; replace it with an
equivalent device instead. Repairs may only be carried out by the manufacturer. The
manufacturer is not liable for damage resulting from noncompliance.
The IP20 degree of protection (IEC 60529/EN 60529) of the device is intended for use
in a clean and dry environment. Do not subject the device to mechanical and/or thermal
loads that exceed the specified limits.
To protect the device against mechanical or electrical damage, install it in suitable
housing with an appropriate degree of protection according to IEC 60529.
The device complies with the EMC regulations for industrial areas (EMC class A).
When used in residential areas, the device may cause radio interference.
Only specified devices from Phoenix Contact may be connected to the 12-pos.
S-PORT interface.
This device is not designed for use in atmospheres with a risk of dust explosions.
If dust is present, the device must be installed in suitable approved housing, taking the
surface temperature of the housing into consideration.
WARNING: Risk of electric shock
During operation, certain parts of the devices may carry hazardous voltages. Disregarding this warning may
result in serious personal injury and/or damage to equipment.
Provide a switch/circuit breaker close to the device, which is labeled as the disconnect device for this de-
vice or the entire control cabinet.
Provide overcurrent protection (I 6 A) in the installation.
Disconnect the device from all power sources during maintenance work and configuration (for SELV or
PELV circuits the device can remain connected).
The housing of the device provides basic insulation against the neighboring devices for 300 Vrms. If sev-
eral devices are installed next to each other, this must be taken into consideration and additional insulation
may have to be installed. If the neighboring device is equipped with basic insulation, no additional insula-
tion is required.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phoenix Contact RAD-AI4-IFS and is the answer not in the manual?

Phoenix Contact RAD-AI4-IFS Specifications

General IconGeneral
BrandPhoenix Contact
ModelRAD-AI4-IFS
CategoryTransceiver
LanguageEnglish

Related product manuals