CO check
- Remove the exhaust gases outlet cap on the ex-
haust pipe
- Using the supplied washer, install the exhaust
gases collection kit fitting onto the pipe, as shown
in the figure.
- Correctly orientate the components as shown in
the picture
- Shut the gas outlet on the tool
- Start the engine and let it warm up
- Shut the engine down
- Disconnect the SAS check valve vacuum hose
shown in the figure.
- Seal the connection using a conical a cap.
Maintenance Fly 125 - 150 4T