Indicates that the power and signal lines on the
transducer terminals are crossed over, or the signal
line is shorted to earth.
P901 Echo Confidence1
This parameter displays the most recent echo confidence from the
transducer. It is useful to help find the best mounting location for the
transducer, where you should aim to get the highest figure. It is a percentage
of confidence that the echo reporting the level is the correct one.
P902 Echo Strength1
This parameter displays the most recent echo strength figure for the
transducer, where a higher figure indicates a better returned echo.
P903 Average Noise1
This is the mean noise reading for the transducer. It is measured while the
transducer is not firing, and gives an indication of the average amount of
electrical noise present on the cabling.
P904 Peak Noise1
This is the peak noise reading for the transducer. It is measured while the
transducer is not firing, and gives an indication of the maximum amount of
electrical noise present on the cabling.
P905 Sensitivity
This parameter determines the sensitivity of the unit. Please consult Pulsar
for further information and assistance on changing the value of this
parameter.