Q1: Get/Set Sideband
Set: Set sideband; 1 sets Lower Sideband (LSB), any other value sets Upper Sideband (USB). The
setting is for the current operating session only and is not written to EEPROM.
Get: Get sideband; 0 = USB, 1 = LSB
Q2: Get/Set VFO A frequency – same as FA
Set: Set default operating frequency.
Get: Get default operating frequency.
Q3: Get/Set VOX Enable
Set: Set VOX enable: 1 enables VOX, 0 disables VOX. The setting is for the current operating
session only and is not written to EEPROM.
Get: Get VOX enable; 1 = Enabled, 0 = Disabled
Q4: Get/Set TX Rise Threshold
Set: Set TX Rise Threshold, which should be a percentage number between 0 and 99 (see
description elsewhere in this manual). The default setting of 80 is normally appropriate. The
setting is for the current operating session only and is not written to EEPROM.
Get: Get TX Rise Threshold value
Q5: Get/Set TX Fall Threshold
Set: Set TX Fall Threshold, which should be a percentage number between 0 and 99 (see
description elsewhere in this manual). The default setting of 60 is normally appropriate. The
setting is for the current operating session only and is not written to EEPROM.
Get: Get TX Fall Threshold value
Q6: Get/Set Cycle Min parameter
Set: Set Cycle Min parameter (see description elsewhere in this manual). The setting is for the
current operating session only and is not written to EEPROM.
Get: Get Cycle Min parameter value
Q7: Get/Set Sample Min parameter
Set: Set Sample Min parameter (see description elsewhere in this manual). The setting is for the
current operating session only and is not written to EEPROM.
Get: Get Sample Min parameter value
Q8: Get/Set Discard parameter
Set: Set Discard parameter (see description elsewhere in this manual). The setting is for the
current operating session only and is not written to EEPROM.
Get: Get Discard parameter value
QMX operang manual; rmware 1_00_012 84

Other manuals for QRP Labs QMX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QRP Labs QMX and is the answer not in the manual?

QRP Labs QMX Specifications

General IconGeneral
BrandQRP Labs
ModelQMX
CategoryTransceiver
LanguageEnglish

Related product manuals