The complete list of log events is as follows:
Event Explanation Example Comment
Power up Occurs every
power up
Start
1_00_001
Shows the start event and version number
Set VFO VFO frequency
change
VFO.A
7074000
VFO A is set to 7.074 MHz. VFO B is also available
Band
change
Band is set to a
new value
Band 40m An error is generated for bands not supported.
TX Radio switched
to Transmit
TX Can be either by CAT command or by VOX
RX Radio switched
to Receive
RX Can be either by CAT command or by VOX
VFO
Mode
VFO mode set
to A, B, or Split
VFO Mode
A
An error is generated for any attempt other than A, B
or Split
Split ON/
OFF
CAT Split on/off
command SP
Split ON
Clk2 Signal generator
frequency is set
Clk2
7075000
Gain Set audio gain Gain 25 Audio gain is set by the AG; CAT command
RIT Down RIT down CAT
command
RIT DN
500
RIT Up RIT up CAT
command
RIT UP
500
CAT Every CAT
command
IF; Every CAT command generates a log entry event
QMX operang manual; rmware 1_00_012 88