Chapter 5 Troubleshooting and Diagnostics
Error Codes
38 LTO Ultrium 8-Slot Autoloader User’s Guide
3 Press Enter to begin the test. The Test Count displays the number of
load-calibrate-unload cycles that have been completed during the
test.
4 Press the
Cancel button to end the test.
Error Codes 5
Table 5 Oviewview of
Error Codes
Table 6 Robotic
Control Errors
Error Code Hex Notation Error Belonging to
80 - 8F Robotic control errors
90 - 96 Function errors
A0 - A5 Low level axis errors
B0 - B7 Electronic hardware errors
BA - BF Drive errors
Error Code Hex Notation Description
80 No error.
81 Invalid command error. This error
indicates that the Loader received an
undefined command or an invalid
parameter to a command.
82 Device status not suitable to execute this
command. If the robotics are busy, some
commands can't be executed at the same
time. This error will indicate a probable
violation. This is not an error condition,
but does result in busy being reported to
the host for the requested SCSI
command.