Chapter 5 Troubleshooting and Diagnostics
Error Codes
LTO Ultrium 8-Slot Autoloader User’s Guide 39
Table 7 Function
Errors
83 Inventory not valid. The cartridge
inventory is not valid, because of
manual changes or previous fatal errors.
In such case, the inventory must be
updated by appropriate
Set Slot Status
commands.
84 Source element not ready. The transport
source element is empty.
85 Destination element not ready. The
destination element is already full.
86 Access door not possible. An attempt to
access the door is rejected, while a media
removal is prevented.
87 Timeout. A timeout condition occurred.
88 Communications error during loop-
back.
89 Timeout detected by loader on BHC
testing.
8F No error after autoloader recovery.
Error Code Hex Notation Description
90 Mechanical initialization failure. The
robotic wasn't able to get into its safe
mechanical init position. Manual
intervention will be necessary.
91 Scan failure. Fatal error during cartridge
scan, building up inventory.
92 Preposition failed. Belt positioning error
during the
Preposition command.
Error Code Hex Notation Description