Fine fi lter cartridge 90 µm 043054
Caps 1" with chain (REMS Multi-Push) 115619
Plugs 1" with chain (suction/pressure hoses) 115620
Plugs ½" with chain (REMS Multi-Push) 115624
Caps ½" with chain (high-pressure hose) 115623
Pressure gauge 6 MPa/60 bar /870 psi 115140
Fine scaled pressure gauge 1.6 MPa/16 bar/232 psi, 115045
Fine scaled pressure gauge 250 hPa/250 mb
ar/3.6 psi, 047069
1.3 Applic
ations
D
evice storage temperature ≥ 5°C
Water temperature 5°C – 35°C
Ambient temperature 5°C – 40°C
pH value 6,5 – 9,5
Smallest test volum
e
approx. 10 l
Compressor
Compressor
Operating pressure ≤ 0.8 MPa/8 bar/116 psi
Oil separation rate oil-free
Extraction rate ≤ 230 Nl/min
Compressed air vessel volume (Fig. 1 (35)) 4.9 l
Condensation and particle fi lter
5 µm
Flushing of pipe systems
Flushing of pipe systems
Flushing water connections DN 25, 1"
Water pressure pipe network ≤ 1 MPa/10 bar/145 psi
Water pressure when fl ushing with compressed air ≤ 0.7 MPa/7 bar/101 psi
Water fl ow rate ≤ 5 m³/h
Pipe diameter installation ≤ DN 50
, 2"
Pressure testing
Pressure testing
o
f drinking water installations
f drinking water installations
P
ressure test with compressed air ≤ 0.4 MPa/4 bar/58 psi
Reading accuracy < 200 mbar 1 hPa/1 mbar/0.015 psi
Reading accuracy ≥ 200 mbar 100 hPa/0,1 bar/1.5 psi
Pressure test with water ≤ 1.8 MPa/18 ba r/261 psi
Reading accuracy
0.02 MP
a/0.2 bar/3 psi
Pressure testing of gas installations
Pressure testing of gas installations
Pressure te
st with compressed air ≤ 0.3 MPa/3 bar/44 psi
Reading accuracy < 200 mbar 10 Pa/0,1 mbar/0.002 psi
Reading accuracy ≥ 200 mbar 100 hPa/0,1 bar/1.5 psi
1.4 Electrical/electronic data
230 V~; 50 Hz; 1,500 W
110 V~; 50 Hz; 1,500 W
Type of protecti
on terminal box IP 44
Type of protection device, motor IP 20
Protection class I
Operating
mode (continuous operation) S 1
Screen (LCD) 3.0"
Resolution 128 × 64 bits
Data transfer with USB stick USB port
Printer, battery Ni-Mh 6 V
---
; 800 mAh
Charger printer Input 100 240 V~; 50 60 Hz; 0.15 A
Output 5 V
---
; 680 m
A
1.5 D
imensions L × W × H
570 ×
370 × 530 mm (22.4"
× 14.6"
× 20.9")
Paper r
oll printer B × Ø
57 × ≤ 33 mm
1.6
W
eight
REMS Multi-Push SL 36.7 kg (81 lb)
REMS Multi-Push SLW 39.0 kg (86
lb)
1.7 Noise information
Work place-related
Emission value L
PA
= 73 dB(A); L
PA
= 73 dB(A); L
PA
WA
= 73 dB(A); L
WA
= 73 dB(A); L
= 92 dB(A); K = ± 1 dB
2 Start-up
CAUTION
CAUTION
Transport weights above 35 kg must be carried by at least 2 persons.
NOTICE
REMS Multi-Push is not intended/suitable for permanent connection to the
installation. Disconnect all hoses from the installation after completing the work.
REMS Multi-Push may not be operated unattended.
2.1 Electrical connection
WARNING
Caution: Mains voltage present!
Before connecting the electronic ushing and
pressure testing unit, check whether the voltage given on the rating plate corre-
sponds to the mains voltage. Only use sockets/extension leads with a functioning
PE contact. The function of the PRCD fault current circuit breaker (Fig. 1 (1))
must be checked every time before start-up and before beginning work:
1. Plug the mains plug into the socket.
2. Press the RESET button (2), the PRCD control lamp (Fig. 1 (39)) lights red
(operating state).
3. Pull out the mains plug, the PRCD control lamp (39) must go out.
4. Plug the mains plug back into the socket.
5. Press the RESET button (2), the PRCD control lamp (39) lights red (oper-
ating state).
6. Press the TEST button (3), the PRCD control lamp (39) must go out.
7. Press the RESET button (2) again, the PRCD control lamp (39) lights red.
The control lamp (Fig. 2 (5)) lights green. REMS Multi-Push is ready for
operation after about 10 s.
WARNING
If the described functions of the PRCD fault current circuit breaker (Fig. 1 (1))
are not fulfi lled, the device may not be used. There is a danger of electric shock.
The PRCD fault current circuit breaker tests the connected device, not the
installation before the socket nor interconnected extension leads or cable reels.
On building sites, in a wet environment, indoors and outdoors or under similar
installation conditions, only operate the electronic fl ushing and pressure testing
unit on the mains with a fault current protection switch (FI switch) which interrupts
the power supply as soon as the leakage current to earth exceeds 30 mA for
200 ms. A cable cross-section that corresponds to the power of the electronic
ushing and pressure testing unit must be selected when using an extension
lead.
Flushing
Ingredients
Testing
Compressed Air Pump
Memory Manager
Press the On/Off button on the input and control unit's operating panel (Fig. 2
(4)) for approx. 2 s, then release it. REMS Multi-Push is switched on and the
compressor switches on. The screen (6) is illuminated and the Logo REMS
Multi-Push logo appears followed by the Start menu:
2.2 Menu structure and on-screen displays
Five main programs of the REMS Multi-Push are displayed in the Start menu:
Flushing, Ingredients, Testing, Compressed Air Pump, Memory Manager. The
screen display contains a maximum 5 lines with 20 characters each. Lines with
defaults or test values are displayed
language-independently
with physical
formula symbols, a uniform verbal abbreviation and the value of the test crite-
rion in the sub-routines. These have the following meanings:
p refer bar xxx reference test pressure bar
p refer mbar xxx reference test pressure mbar
p actual bar xxx actual test pressure bar
p actual mbar xxx actual test pressure mbar
p diff bar xxx differential test pressure bar
p diff mbar xxx differential test pressure mbar
t stabi min xxx stabilisation/wait time min
t test min xxx test time min
Δ > 10K difference >10°C (10 Kelvin) water/environment
PfS press fi tting system (ZVSHK)
P+M load test plastic + metal
p H
2
O bar water pressure
v H
2
O m/s minimum fl ow speed
t H
2
O min ushing/disinfecting/cleaning/preservation time
n H
2
O n-times water change
VA H
2
O l volume of the fl ushing section
VS H
2
O l/min volume fl ow
V H
2
O l used water volume
File no. memory location no. for measuring log
max. DN largest rated diameter
Enter next screen display
Esc previous screen display or cancel
Ver. Software version software
2.3 Settings menu
NOTICE
The defaults for the different test criteria in the Settings menu of the REMS
Multi-Push are taken from the EN 806-4:2010 or the information leafl et “Leak
tests of drinking water installations with compressed air, inert gas or water”
(January 2011) of the German Central Association for Sanitary, Heating and
Air Conditioning (ZVSHK) as well as the Technical Rule “Technical Rule for
Gas Installations Worksheet G 600 April 2008 DVGW-TRGI 2008” of the DVGW
German Gas and Water Association. All defaults for the test programs can be
edited by the user in the Settings
menu
and in the Flushing, Test with compressed
air, Test with water and Compressed Air Pump
programs
programs
. Changes in the
Settings
menu
are saved, i.e. they reappear the next time the REMS Multi-Push
is switched on. If the defaults are only changed in one of the
programs
programs
, the
original defaults appear again the next time the REMS Multi-Push is switched
on. Reset resets all defaults to factory settings and the language to German
and the date, time, units formats to DD.MM.YYYY, 24 h, m/bar.
Attention:
The user is solely responsible for transferred or newly entered
test criteria (test sequences, pressures and times) or defaults in the
individual programs and the conclusions from the tests.
The respective national safety provisions, rules and regulations valid for
the application site must be considered and observed.
Before using the REMS Multi-Push, check whether the respective latest version
software is installed on the input and control unit. Select the Settings menu and
21

Table of Contents

Other manuals for REMS Multi-Push SL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REMS Multi-Push SL and is the answer not in the manual?

REMS Multi-Push SL Specifications

General IconGeneral
BrandREMS
ModelMulti-Push SL
CategoryWater Pump
LanguageEnglish

Related product manuals