• The M102 has a 2-segment display [1]. A letter-number code is used to designate an SC code. For
example, "c6" designates "SC101". (These 2-digit codes are included in the SC tables below.) The
alert lamp [2] also lights when an error occurs.
[A]: CHN, [B]: NA, [C]: EU
•
The M103 has a 7-segment display (1) so the full SC number, "SC101" can be shown on the
operation panel display. When an error occurs the alert lamp (2) lights and the fax speaker will
sound an alert. (The M103 is the only machine with a speaker.)
• For all models of this series, the M101, M102, and M103, the Smart Organizing Monitor
can be used to display the most recent SC codes in the Error History box of the Service Mode
screen. ( p.170 "Smart Organizing Monitor Service Mode")
Executing Fuser SC Reset
1. After correcting the problem, open Smart Organizing Monitor.
2. Enter the service mode to display the Service Mode screen.
6. Troubleshooting
202