Rinstrum - 5200 Communications Manual Rev 1.2
0025-605-120 Page 55
2.4.43. ZST: Zero Settings
Set the various options associated with zero balance.
General Details
No. of Parameters Save Changes Changes Used Increment Trade Counter
4 With TDD1 Immediately Yes (except for Zero on
Startup)
Parameter Details
Parameter Description Range Default Required
1 Initial Zero 0
1
OFF
ON
0 No
2 Zero
Tracking
0
1
to
12
OFF
0.5d in 1sec
5d in 0.2sec
0 No
3 Zero Range 1
2
3
4
–20% to 20%
–100% to 100%
–2% to 2%
–1% to 3%
3 No
4 Zero Dead
Band
0 to fullscale 0 No
Example
Command Response Details
S01;
ZST?; 0,0,3,0 CRLF Query current zero settings
ZST1; 0 CRLF Change to zero on startup
ZST,,,10; 0 CRLF Change Zero Dead Band to 10
ZST?; 1,0,3,10 CRLF Query new settings
TDD1; 0 CRLF Save settings