2.3.4. Termination
Termination characters are sent to define the end of a command, query or
response. The following are permissible termination characters:
Termination Character ASCII Code(s)
; 59
LF 10
CRLF 13 10
LFCR 10 13
For example, ADR?; is the same as ADR? CRLF.
Note: The 5200 invariably uses CRLF as the termination of its responses.
2.3.5. Trade Counter
All trade relevant functions are guarded by the trade counter. There is no difference
in changing settings via the communications interface or via the front panel. If the
counter reaches 60000 the 5200 operation is blocked and it must be returned to the
factory.
Note that the 5200 does not check to see if the new data is different from the old
data before incrementing the Trade Counter, so sending IAD1,6000 will increment
the counter even if the 5200 is already setup with a fullscale of 6000 kg.
It is possible to block all changes to trade relevant parameters by setting a Full
Setup Passcode. If such a passcode has been set, trade parameters can only be
changed via the serial port after a PCD command has been sent with the correct