Chapter 4 FactoryTalk Batch Recipe Editor introduction
60
5. Choose the Selection Tool and double-click inside the text box. Type
Reduce the agitation speed to 20 RPM if the mixture begins to
separate.
6. Select outside the text box when the comment is complete.
When you remove a step from the recipe, the FactoryTalk Batch Recipe Editor
will reconfigure the links and transitions accordingly. However, sometimes
the links and transitions are complex and you may have to redo the links and
reconfigure the transitions manually.
FactoryTalk Batch is capable of performing looping at all levels of the
procedural model. Not only is this a powerful recipe management tool, it is a
simple task to complete.
To add a continuous loop to the sample unit procedure:
1. Select Go Up on the toolbar twice to move to the
CLS_SWEETCREAM_UP:1 unit procedure.
2. Select Transition Tool. Place the pointer to the right of the existing
transition labeled CLS_SWEETCREAM_UP:1.STATE = COMPLETE,
and then select to add an undefined transition.
3. Select the Link Tool button.
Remove steps
Add a continuous loop to
the sample unit procedure

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation FactoryTalk Batch and is the answer not in the manual?

Rockwell Automation FactoryTalk Batch Specifications

General IconGeneral
BrandRockwell Automation
ModelFactoryTalk Batch
CategoryPower Supply
LanguageEnglish

Related product manuals