Chapter 5 FactoryTalk Batch View introduction
79
7. Select the Acknowledge button. The Acknowledge dialog box opens
showing the default value as 0. The allowable range of values is 0 to
5000.
8. Type 40, and then select the Acknowledge button. The phase continues
to run.
As the phase runs, you can use the command buttons to Hold, Restart,
Abort, Stop, Pause, Resume the phase.
9. When the phase completes, select the Reset command button, and
then select Yes to confirm the reset.
You can run this phase as many times as necessary to test it. When you
are done testing, release control back to FactoryTalk Batch so the phase
can run as part of a recipe.
10. Select the Release command button, and then select Yes to confirm the
release.
A procedure stops running if a phase is unable to acquire the needed
equipment. The FactoryTalk Batch Server displays ACQUIRING1 on the SFC
at the transition above that phase and that is where you begin your
investigation to determine the cause of the arbitration issue.
In this exercise you manually acquire a phase, run a procedure to view an
arbitration situation, and then resolve the arbitration issue.
Resolve arbitration issues

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation FactoryTalk Batch and is the answer not in the manual?

Rockwell Automation FactoryTalk Batch Specifications

General IconGeneral
BrandRockwell Automation
ModelFactoryTalk Batch
CategoryPower Supply
LanguageEnglish

Related product manuals