Chapter 6 Install and Replace Components
3. On touch screen only terminals, remove the two screws that
secure the small metal plate to the back of the display module.
4. Disconnect the touch screen connector.
5. Remove the screws from the back of the display module.
The number of screws varies for each terminal type.
6. Remove the sealing gasket.
Plate
Touch Screen Connector
Display Module Bezel