-58-
Electrical Adjustments
Equipment luminance meter
Input mode Computer [RGB(Analog)]
Image mode Dynamic
Input format 720p computer signal
1. Receive the 100% whole-white signal.
2. Enter the service mode.
3. Select group/item no. “
4 - 6” and measure the lumi-
nance on the screen with the luminance meter. It is
A for the reading of luminance meter.
4. Change the signal source to the 50% whole-white
signal.
5. Change data value to make the reading of luminance
meter to be A x 30 ±2%.
m Panel Luminance adjustment [Dynamic]
Input mode Computer [RGB(Analog)]
Image mode Dynamic
Input format 720p computer signal
1. Receive the 50% whole-white signal.
2. Enter the service mode.
3. Select group no. “4”, item no. “7” (Blue) or “8” (Red),
and change data values respectively to make a prop-
er white balance.
, White Balance adjustment [Dynamic]
Equipment luminance meter
Input mode Computer [RGB(Analog)]
Image mode Natural
Input format 480p computer signal
1. Receive the 100% whole-white signal.
2. Enter the service mode.
3. Project only one color component to the screen.
4. Select group/item no. “4 - 155” and measure the
luminance on the screen with the luminance meter.
It is B for the reading of luminance meter.
5. Change the signal source to the 50% whole-white
signal.
6. Change data value to make the reading of luminance
meter to be B x 22 ±2%.
Item no.
Screen
4 - 155 Only green color picture
4 - 156 Only blue color picture
4 - 157 Only red color picture
. Panel Luminance adjustment [Natural]
Input mode Computer [RGB(Analog)]
Image mode Dynamic
Input signal 50% whole-white pattern 720p comput-
er signal
1. Enter the service mode.
2. Select group/item no. "4 - 114", and change data
value from “0” to “2”. (Flicker adjustment mode
...See Note)
3. Project only one color component to the screen.
4. Change data value to obtain the minimum flicker
for each color on the screen.
5. After this adjustment, select group/item no. "4 -114",
and change data value from “2” to “0” for normal
operation.(Or turn off the projector, then this data
value will be reset to “0” .)
Item no. Screen
3 - 0 Only green color picture
3 - 1 Only blue color picture
3 - 2 Only red color picture
Note:
The FRP signal (common electrode reverse signal)
works at 120Hz, so flicker is invisible for human eyes.
The service mode "4 - 114" can change the FRP sig-
nal from 120Hz to 60Hz, and flicker can be seen.
n Common Center adjustment