133
PBLU code programming
You can specify the range of PBLU codes available for the register.
Programming 1 for start code and 1000 for end code
Functional programming for the printer
You can program the printing density of the receipt/journal printer.
*AB: Printing density (00 – 99)
00 = 80% for standard density
50 = 90% for standard density
99 = 100% for standard density
Programming “90% for standard density”
2990
.@
50
Ç
PrintKey operation
Example
2990
.
Ç
*AB
To program zero
@
Procedure
2990
PGM 2
2810
.@
1
@
1000
a
PrintKey operation
Example
2810
.
@ @
a
Start code
(1 - 9999)
To program only one code
End code
(1 - 9999)
Procedure
2810
PGM 2
ER-A410/A420(SEC)-4 03.12.22 0:20 PM Page 133