141
Programming of RS-232C interface
Online terminal number
Transmission line form system
* Item: Selection: Entry:
A Sensing of the CI signal No 0
Sensing 1
B Line form Full duplex system 0
Half duplex system 1
Functional programming
* Item: Selection: Entry:
A Selection of print data send/data download and Data download and upload 0
upload
Print data send 1
B Baud rate (38400/19200/9600/4800 bps) 4800 bps 4
The selected baud rate is used for on-line
9600 bps 5
communications and print data sending.
19200 bps 6
It is not used for the data backup function.
38400 bps 7
Start code and end code
* ABC: Start code (000 – 127)
DEF: End code (000 – 127)
Time out setting
6115
.
Ç
Time out time
(1 255 sec)
@
Procedure
6113
.
Ç
*ABCDEF
To program zero
@
Procedure
6112
.
Ç
*AB
To program zero
@
Procedure
6111
.
Ç
*AB
To program zero
@
Procedure
6110
.
Ç
Terminal no.
(max. 6 digits)
To program zero
@
Procedure
6220
61156113611261116110
PGM 2
ER-A410/A420(SEC)-4 03.12.22 0:20 PM Page 141

Table of Contents

Other manuals for Sharp ER-A410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp ER-A410 and is the answer not in the manual?

Sharp ER-A410 Specifications

General IconGeneral
BrandSharp
ModelER-A410
CategoryCash Register
LanguageEnglish

Related product manuals