Technical information
8.4 Mechanical ambient conditions
Comfort Panels
190 Operating Instructions, 07/2017, A5E36770603-AB
Emission of radio interference
The following table shows the emitted interference from electromagnetic fields according to
EN 61000-6-4, measured at a distance of 10 m.
From 30 to 230 MHz < 40 dB (μV/m) quasi-peak
< 47 dB (μV/m) quasi-peak
Notes about usage (Page 30)
Mechanical ambient conditions
8.4.1
The following information is for a device that is transported and stored in its original
packaging.
The device meets the requirements according to IEC 60721-3-2 Class 2M2 with the following
amendments and limitations:
Free fall ≤ 1 m
Vibration according to IEC 60068-2-6 5 .. 8.4 Hz, deflection 3.5 mm
8.4 ... 500 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
2
The following information applies to a device installed according to the specifications in these
operating instructions.
The device was tested based on IEC 60721-3-3 Class 3M3 with the following amendments
and limitations:
Vibration according to IEC 60068-2-6 5 ... 8.4 Hz, deflection 3.5 mm
8.4 ... 150 Hz, acceleration 1 g
Shock according to IEC 60068-2-27
2
Shock pulses within the specified range can be transferred to the display but do not impact
the functionality of the device.