Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
156 Configuration Manual, 10/2021, C79000-G8976-C475-03
The table contains the following columns:
• Select
Select the check box in a row to be deleted.
• SMTP Server
Shows the IP address or the FQDN (Fully Qualified Domain Name) of the SMTP
server to which the entry relates.
• Send
When enabled, the device sends an e-mail to this receiver.
• SMTP Receiver Email Address
Shows the e-mail address to which the device sends an e-mail if a fault occurs.
Procedure
Configuring an SMTP receiver
1. Select the required "SMTP Server".
2. Enter the SMTP receiver email address.
3. Click the "Create" button. A new entry is generated in the table.
4. Activate the "Send" option for the entry.
5. Click the "Set Values" button.
4.4.8 DHCP
4.4.8.1 DHCP Client
If the device is configured as a DHCP client, it starts a DHCP request. As the reply to the
query the device receives an IPv4 address from the DHCP server. The server manages an
address range from which it assigns IPv4 addresses. It is also possible to configure the
server so that the client always receives the same IPv4 address in response to its
request.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals