EasyManuals Logo
Home>Siemens>Switch>SIMATIC NET SCALANCE SC646-2C

Siemens SIMATIC NET SCALANCE SC646-2C User Manual

Siemens SIMATIC NET SCALANCE SC646-2C
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #264 background imageLoading...
Page #264 background image
Configuring with Web Based Management
4.6 "Layer 3" menu
SCALANCE SC-600 Web Based Management (WBM)
264 Configuration Manual, 10/2021, C79000-G8976-C475-03
4.6.2.2 Masquerading
On this WBM page, you enable the rules for IP masquerading.
Description
The table has the following columns:
• Interface
Interface to which the setting relates. Only interfaces with configured subnets are
available.
• Enable Masquerading
When enabled, with each outgoing data packet sent via this interface, the source IP
address is replaced by the IP address of the interface.
4.6.2.3 NAPT
On this WBM page, you can configure a port translation in addition to the address
translation.
The following port translations are possible:
• From a single port to the same port:
If the ports are the same, the frames will be forwarded without port translation.
• From a single port to a single port
The frames are translated to the port.
• From a port range to a single port
The frames from the port range are translated to the same port (n:1).
• From a port range to the same port range
If the port ranges are the same, the frames will be forwarded without port translation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals