Configuring with Web Based Management
4.6 "Layer 3" menu
SCALANCE SC-600 Web Based Management (WBM)
274 Configuration Manual, 10/2021, C79000-G8976-C475-03
Procedure
1. Enter the network address of the destination in the "Destination Network" input box.
2. Enter the corresponding subnet mask in the "Subnet Mask" input box.
3. For "Interface", select the entry "auto".
4. Enter the gateway in the "Gateway" input box.
5. Enter the weighting of the route in "Administrative Distance".
6. Click the "Create" button. A new entry is generated in the table.
7. Click the "Set Values" button.
4.6.4 VRRPv3
4.6.4.1 Router
Introduction
Using the "Create" button, you can create new virtual routers. A maximum of 16 virtual
routers can be configured. You can configure other parameters on the "Configuration"
tab.
Note
•
You can use VRRPv3 on VLAN interfaces.
Requirement
For the incoming packets to be forwarded to the device, enable the predefined IPv4 rule
"VRRP".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals