Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
210 Configuration Manual, 10/2021, C79000-G8976-C475-03
Table 2 has the following columns:
• Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
• Setting
Select the setting from the drop-down list. You have the following options:
– Up
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
– Down
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
– "-" (disabled)
The error handling is not triggered.
Procedure
Configure error monitoring for a port
1. From the relevant drop-down list, select the options of the slots / ports whose
connection status you want to monitor.
2. Click the "Set Values" button.
Configure error monitoring for all ports
1. Select the required setting from the drop-down list of the "Setting" column.
2. Click the "Copy to Table" button. The setting is adopted for all ports of table 2.
3. Click the "Set Values" button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals