Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
210 Configuration Manual, 10/2021, C79000-G8976-C475-03
Table 2 has the following columns:
• Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
• Setting
Select the setting from the drop-down list. You have the following options:
– Up
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
– Down
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
– "-" (disabled)
The error handling is not triggered.
Procedure
Configure error monitoring for a port
1. From the relevant drop-down list, select the options of the slots / ports whose
connection status you want to monitor.
2. Click the "Set Values" button.
Configure error monitoring for all ports
1. Select the required setting from the drop-down list of the "Setting" column.
2. Click the "Copy to Table" button. The setting is adopted for all ports of table 2.
3. Click the "Set Values" button.