Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
243
• Edge Type
Specify the type of the "Edge Port". You have the following options:
– "-"
Edge port is disabled. The port is treated as a "no Edge Port".
– Admin
Select this option when there is always an end device on this port. Otherwise a
reconfiguration of the network will be triggered each time a connection is changed.
– Auto
Select this option if you want a connected end device to be detected automatically
at this port. When the connection is established the first time, the port is treated
as a "no Edge Port".
– Admin/Auto
Select these options if you operate a combination of both on this port. When the
connection is established the first time, the port is treated as an "Edge Port".
• Edge
Shows the status of the port.
– Enabled
ï—¦An end device is connected to this port.
– Disabled
There is a Spanning Tree or Rapid Spanning Tree device at this port.
With an end device, a switch can change over the port faster without taking into
account spanning tree frames. If a Spanning Tree frame is received despite this
setting, the port automatically changes to the "Disabled" setting.
• P.t.P. Type
Select the required option from the drop-down list. The selection depends on the port
that is set.
– "-"
Point to point is calculated automatically. If the port is set to half duplex, a point-
to-point link is not assumed.
– P.t.P.
Also with half duplex, a point-to-point link is assumed.
– Shared Media
Even with a full duplex connection, a point-to-point link is not assumed.
Note
Point
-to-point connection means a direct connection between two devices. A
shared media connection is, for example, a connection to a hub.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals