Configuring with Web Based Management
4.5 "Layer 2" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
245
Description
Table 1 has the following columns:
• All Ports
Shows that the settings are valid for all ports.
• Setting
Select the setting from the drop-down list. If "No Change" is selected, the entry in
table 2 remains unchanged.
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
• Port
Shows the available ports.
• Setting
Specify the LLDP functionality. The following options are available:
– Rx
This port can only receive LLDP frames.
– Tx
This port can only send LLDP frames.
– Rx & Tx
This port can receive and send LLDP frames.
– "-" (disabled)
This port can neither receive nor send LLDP frames.
Procedure
1. Select the LLDP functionality of the port from the "Setting" drop-down list.
2. Click the "Set Values" button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals