4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
318 Configuration Manual, 10/2021, C79000-G8976-C475-03
• Source (Range)
Enter the IP address or an IP range that is allowed to receive IP packets.
– Individual IP address
Enter the IPv4 address.
– IP range
Specify the range with the start address "-" end address, e.g. 192.168.100.10 -
192.168.100.20.
– All IP addresses
Specify "0.0.0.0/0".
– DYNAMIC
If the rule set is activated by a user, the placeholder DYNAMIC is replaced by the
IP address of the terminal device used.
Note
Digital input and DYNAMIC placeholder
If the rule set is executed by controlling the digital input, the placeholder
DYNAMIC is repl
aced by the setting for "Dynamic Source (Range)". You configure
the setting in "Security > Firewall > User Specific".
• Destination (Range)
Enter the IP address or an IP range that is allowed to receive IP packets.
– Individual IP address
Enter the IPv4 address.
– IP range
Specify the range with the start address "-" end address, e.g. 192.168.100.10 -
192.168.100.20.
– All IP addresses
Specify "0.0.0.0/0".
• Service
Select the service or the protocol name for which this rule is valid.
• Log
Specify whether or not there should be a log entry every time the rule comes into
effect and specify the severity of the event.
The following settings are available:
– none
The rule coming into effect is not logged.
– info / warning / critical
The rule coming into effect is logged with the selected event severity. The log file
is displayed in "Information" > "Log Tables" > "Firewall Log".

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC646-2C and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC646-2C Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC646-2C
CategorySwitch
LanguageEnglish

Related product manuals