3.1.2 Danger from strong magnetic elds
Occurrence of magnetic elds
Motor components with permanent magnets generate very strong magnetic elds. In the no-
current condition, the magnetic eld strength of the motors comes exclusively from the
magnetic elds of components equipped with permanent magnets. Additional electromagnetic
elds occur in operation.
Components with permanent magnets
The rotors of the 1FW6 built-in torque motors described in this manual contain permanent
magnets.
Figure3-1 Rotor
DSSUR[
DSSUR[
0DJQHWLFIOX[GHQVLW\LQP7
'LVWDQFHLQPP
Figure3-2 Schematic representation of the static magnetic eld of a rotor, as a function of distance
Description
3.1Technical features and ambient conditions
1FW6 built-in torque motors
28 Operating Instructions, 09/2022, A5E52220812B AA