9. Check that the rotor can rotate freely. Ensure that the spacer 󹪝lm and any other foreign bodies
are completely removed from the air gap.
10.Connect the coolant lines.
11.Connect the power and signal lines.
5.8 Mechanical adjustment angle and EMF phase position
The EMF phase positions of motors connected in parallel must match one another. The
maximum deviation within a particular EMF phase position may be 10° (or +/-5°) electrical.
Otherwise, when mounting the motor you must correct the mechanical adjustment angle so
that you maintain the speci󹪝ed tolerance for the EMF phase position.
The relationship between the EMF phase position (electrical angle) and the mechanical
adjustment angle is shown in the following.
Installation
5.8Mechanical adjustment angle and EMF phase position
1FW6 built-in torque motors
80 Operating Instructions, 09/2022, A5E52220812B AA