4.2.1 Packaging speci󹪝cations for air transportation
When transporting products containing permanent magnets by air, the maximum permissible
magnetic 󹪝eld strengths speci󹪝ed by the appropriate IATA Packing Instruction must not be
exceeded. Special measures may be required so that these products can be shipped. Above a
certain magnetic 󹪝eld strength, shipping requires that you notify the relevant authorities and
appropriately label the products.
Note
The magnetic 󹪝eld strengths listed in the following always refer to values for the DC magnetic
󹪝eld speci󹪝ed in IATA packaging instruction953. If the values change, we will take this into
account in the next edition.
Products whose highest 󹪝eld strength exceeds 0.418 A/m, as determined at a distance of 4.6 m
from the product, require shipping authorization. This product will only be shipped with
previous authorization from the responsible national body of the country from where the
product is being shipped (country of origin) and the country where the airfreight company is
based. Special measures need to be taken to enable the product to be shipped.
When shipping products whose highest 󹪝eld strength is equal to or greater than 0.418 A/m,
as determined at a distance of 2.1m from the product, you have a duty to notify the relevant
authorities and appropriately label the product.
When shipping products whose highest 󹪝eld strength is less than 0.418 A/m, as determined
at a distance of 2.1m from the product, you do not have to notify the relevant authorities
and you do not have to label the product.
Shipping originally packed motor components neither has to be disclosed nor marked.
4.2.2 Ambient conditions for long-term storage and transport
Based on DINEN60721-3-1 (for long-term storage) and DINEN60721-3-2 (for transport)
Table 4-4 Climatic ambient conditions
Lower air temperature limit for long-
term storage:
- 5°C (deviates from 3K3)
Lower air temperature limit for trans‐
port:
- 15°C
Upper air temperature limit: + 40° C
Lower relative humidity limit: 5%
Upper relative humidity limit: 85%
Rate of temperature 󹪞uctuations: Max.0.5K/min
Condensation: Not permissible
Formation of ice: Not permissible
Preparation for use
4.2Transporting and storage
1FW6 built-in torque motors
62 Operating Instructions, 09/2022, A5E52220812B AA

Table of Contents

Other manuals for Siemens SIMOTICS T-1FW6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS T-1FW6 and is the answer not in the manual?

Siemens SIMOTICS T-1FW6 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS T-1FW6
CategoryEngine
LanguageEnglish

Related product manuals