Supplementary system components
6.3 TB30 terminal board
SIMOTION D4x5-2
Manual, 02/2012
103
6.3.3.4 Digital I/Os
Table 6- 6 Terminal block X481
Terminal Designation
1)
1 DI 0
2 DI 1
3 DI 2
4 DI 3
5 DO 0
6 DO 1
7 DO 2
8 DO 3
1) DI: digital input, DO: Digital output
Table 6- 7 X481 wiring
Characteristics Type
Connectable cable types:
- Rigid
- Flexible
- Flexible, with end sleeve without plastic sleeve
- AWG/kcmil
Conductor cross-sections:
0.14 mm
2
to 0.5 mm
2
0.14 mm
2
to 0.5 mm
2
0.25 mm
2
to 0.5 mm
2
26 to 20
Stripped length 8 to 9 mm
Tool Screwdriver 0.4 x 2.0 mm
Max. cable length 30 m
Note
An open input is interpreted as "low".
The power supply and the digital I/Os are isolated from the control unit.
Note
With momentary interruptions in the 24 V supply, the digital outputs are deactivated during
this time.