Supplementary system components
6.11 DMC20 DRIVE-CLiQ hub
SIMOTION D4x5-2
Manual, 02/2012
133
6.11 DMC20 DRIVE-CLiQ hub
Properties
The DMC20 and DME20 DRIVE-CLiQ hub modules are used to implement point-to-point
distribution of a DRIVE-CLiQ line. With the DMC20/DME20, an axis grouping can be
expanded with four DRIVE-CLiQ sockets for additional subgroups.
DMC20 is the hub for the control cabinet configuration
DME20 is the hub for use without a control cabinet (IP67 degree of protection).
The modules are especially suitable for applications which require DRIVE-CLiQ nodes to be
removed in groups, without interrupting the DRIVE-CLiQ line and therefore the data
exchange.
Additional references
You will find detailed information about the DMC20/DME20 in the following source:
SINAMICS S120 Control Units and Supplementary System Components
Manual

Table of Contents