Technical data of the D4x5-2
4.6 CompactFlash card
SIMOTION D4x5-2
Manual, 02/2012
85
4.6 CompactFlash card
CompactFlash card
Table 4- 17 CompactFlash Card
Memory capacity 1 GB (order no. 6AU1400-2PA22-0AA0)
Weight 10 g
4.7 Clock
Properties of the real-time clock
The following table lists the properties and functions of the SIMOTION D clock.
Table 4- 18 Clock properties
Properties Meaning
Type Hardware clock (integrated "real-time clock")
Default setting when delivered 12:00 a.m. (date 01.01.2001)
Accuracy
• +25° C
• -40° C ... +85° C
Max. deviation per day:
• ±2 s
• ±5 s
Backup time at least
• 4 days (at 0 ... 25° C)
• With battery in the double fan/battery
module 3 years
Charging time A few minutes
Backup Maintenance-free SuperCap or battery in the
double fan/battery module
With power OFF
In the POWER OFF state, the SIMOTION D clock continues to run during the backup time
(with the exception of the software clock). The backup battery is recharged in the POWER
ON state.
An error message is output if the backup function is defective. When the power is switched
ON, the clock then resumes at the time set at the factory.
If the SIMOTION D4x5-2 is reset to its factory setting, the clock is also reset to the "default
setting when delivered".