EasyManuals Logo
Home>Siemens>Modem>TC35i

Siemens TC35i User Manual

Siemens TC35i
439 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
TC35i AT Command Set
7.18 +++
s
m
obil
e
TC35i_ATC_V02.07 Page 165 of 439 1/30/04
Confidential / Released
7.18 +++ Switch from data mode to command mode
Syntax
Command Description
This command is only available during a data call. The +++ character sequence causes the TA to cancel the data
flow over the AT interface and switch to command mode. This allows you to enter AT commands while maintain-
ing the data connection to the remote device.
To prevent the +++ escape sequence from being misinterpreted as data, it must be preceded and followed by a
pause of at least 1000 ms. The +++ characters must be entered in quick succession, all within 1000 ms.
Note
• To return from command mode to data mode: Enter ATO.
Exec Command
+++
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter

Table of Contents

Other manuals for Siemens TC35i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens TC35i and is the answer not in the manual?

Siemens TC35i Specifications

General IconGeneral
BrandSiemens
ModelTC35i
CategoryModem
LanguageEnglish

Related product manuals