TC35i AT Command Set
16.1 AT+CALA
s
m
obil
e
TC35i_ATC_V02.07 Page 398 of 439 1/30/04
Confidential / Released
EXAMPLE 2
To set a fresh alarm using the same message as in Example 1, simply enter date and time. <n>, <type>,
<text>, <tlength> can be omitted:
When the alarm is executed the URC comes with the same message:
EXAMPLE 3
To configure the alarm mode, e.g. for May 20, 2004, at 8.30h, enter
Next, power down the ME:
When the alarm is executed the ME wakes up to Alarm mode and displays a URC. If available, this line is
followed by the individual
<text> most recently saved. If no individual message was saved only the first line
appears.
16.1.1 Summary of AT commands available in Alarm mode
AT+CALA="04/05/31,08:50:00"
OK
+CALA: Good Morning
AT+CALA="04/05/20,08:30:00"
OK
AT^SMSO
^SMSO: MS OFF
^SYSSTART ALARM MODE
+CALA: Good Morning
AT command Use
AT+CALA Set alarm time
AT+CCLK Set date and time of RTC
AT^SBC In Alarm mode, you can query the present current consumption only and check
whether or not a charger is connected. The battery capacity is returned as 0,
regardless of the actual voltage (since the values measured directly on the cell are
not delivered to the module).
AT^SCTM Query temperature of GSM engine
AT^SBV Monitor battery or supply voltage
AT^SMSO Power down GSM engine