TC35i AT Command Set
11.17 AT+CSMS
s
m
obil
e
TC35i_ATC_V02.07 Page 306 of 439 1/30/04
Confidential / Released
11.17 AT+CSMS Select Message Service
Syntax
Parameter Description
0 GSM 03.40 and GSM 03.41 (the syntax of SMS AT commands is compatible
with GSM 07.05 Phase 2 version 4.7.0; Phase 2+ features which do not require
new command syntax may be supported, e.g. correct routing of messages with
new Phase 2+ data coding schemes)
1 GSM 03.40 and GSM 03.41 (the syntax of SMS AT commands is compatible
with GSM 07.05 Phase 2+ version; the requirement of
<service> setting 1 is
mentioned under corresponding command descriptions).
Test Command
AT+CSMS=?
Response(s)
+CSMS: (list of supported<service>s)
OK
Read Command
AT+CSMS?
Response(s)
+CSMS: <service>, <mt>, <mo>, <bm>
OK
Write Command
AT+CSMS=<service>
Response(s)
+CSMS: <mt>, <mo>, <bm>
OK
ERROR
+CMS ERROR
PIN ASC0 MUX1 MUX2 MUX3
% % % % %
Reference(s)
GSM 07.05
<service>