TC35i AT Command Set
2.4 ATQ
s
m
obil
e
TC35i_ATC_V02.07 Page 33 of 439 1/30/04
Confidential / Released
2.4 ATQ Set result code presentation mode
Syntax
Command Description
This parameter setting determines whether or not the TA transmits any result code to the TE. Information text
transmitted in response is not affected by this setting.
Parameter Description
[0]
(&F)
DCE transmits result code
1 Result codes are suppressed and not transmitted
Exec Command
ATQ[<n>]
Response(s)
If <n>=0:
OK
If <n>=1:
(none)
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter
<n>
(num)(&W)(&V)

Table of Contents